Wismec & Beyond Vape Centurion Manual Operations Guide

Wismec & Beyond Vape Centurion

How to use:

1.Power On/Off:

Unscrew the bottom cover and put one 26650 cell into the battery body. Press the fire button 5 times in quick succession to turn the device on and off. You can also use one 18650 cell with the help of battery sleeve, and then the maximum output power recommended is 75W.

Note: Please adjust the wattage to a proper range to match your atomizer before using. Also, for safety reasons, please refrain form using damaged batteries, i.e., dents, torn wrapping, burnt, etc.

2.Stealth Function:

While the device is on, simultaneously hold the fire button and the down button. This will switch the screen display on and off.

3.Resistance Lock Function:

While the device is on, simultaneously hold the fire button and the up button to enter Resistance Lock mode. To disable resistance lock, repeat the procedure.(Note: Such operation should be carried out at room temperature.)

4.Adjustment Lock function:

While the device is on, simultaneously press the up and down buttons. This will Lock and Unlock the adjustment button functions

5.Micro USB Port Function:

The USB port can be used for upgrading firmware, but it is recommended that the battery is removed to charge.

6.Switch the Display Mode:

To rotate the screen display 180 degrees, press the up and down buttons simultaneously in shutdown(power off) state.

Shift among TC-Ni/TC-Ti/TC-SS/TCR/VW/Bypass Mode

When the device is powered on, press the fire button 3 times in quick succession to enter the mode switching state. By pressing the up or down button to shift among TC-Ni, TC-Ti, TC-SS, TCR M1, TCR M2, TCR M3, VW and Bypass mode.

TC-Ni/TC-Ti/TC-SS/TCR Mode:

TC-SS Mode:

The newly added TC-SS mode is suitable to SS316 coil.

TCR Mode:

TCR(Temperature Coefficient of Resistance) Mode is a new vaping mode introduced by Wismec. In this mode users can set the parameters according to the TCR of a coil.

The Setting of TCR Mode:

In powered-off state, keep pressing the fire button and the up button simultaneously, then enter the following into the TCR menu:

  1. Press the up or down button to choose among TCR M1, M2 and M3;
  2. Press the fire button to confirm the mode you have chosen;
  3. Press the up or down button to increase or decrease the parameter according to the TCR of the coil;
  4. Keep pressing the fire button or leave the interface for approximately 10 seconds to confirm.

                                 TCR value range of Beyond Vape Centurion for your reference

Note:

1. The TCR value in the sheet is 10 multiplied by the actual TCR.

2.The TCR value range for Beyond Vape Centurion is 1-1000.

Supplementary TC Modes Functions:

Wattage adjustment:

In TC modes, press the fire button 4 times in quick succession to enter the menu, press the up button to increase wattage and the down button to decrease wattage. Long pressing the up or down button will make the wattage setting rapidly increase or decrease.

Temperature adjustment:

In TC modes, the temperature can be adjusted from (100-315°C or 200-600˚F) with the up and down buttons.

Shift between °C and ˚F:

If you increase the temperature to 315 °C, and continue to press the up button, the temperature readings will automatically change to the lowest Fahrenheit (200˚F). Equally, if the temperature is decreased below the minimum (100 °C), the unit will change back to ˚F automatically, and the temperature will start to decrease from 600˚F.

Note:

In TC modes, be careful to attach new atomizers that have cooled to room temperature. If a new atomizer has not cooled down before attaching, the temperature may read and protect incorrectly until the new atomizer cools.

When you connect a new atomizer or disconnect and reconnect your existing atomizer, the device will prompt you to confirm this change and a message will prompt “new coil up same down”. Press the up button to confirm that a new atomizer has been attached. Press the down button to confirm that the same atomizer has been reconnected.

When using non-TC coils or TC coils with a resistance higher than 1.5ohm in TC modes, the device will automatically switch to VW mode.

VW Mode:

In this mode, output wattage can be adjusted from 1W to 100W with the up and down buttons.

Bypass Mode:

Bypass mode is a direct output mode of voltage. In this mode, the internal chip is “bypassed” and the supporting atomizer resistance is 0.1-3.5ohm.

Malfunction Indication and Protection:

No Atomizer Alert:

When the device does not detect an atomizer, the OLED screen will display “No Atomizer”.

Atomizer Low Alert:

When the resistance of atomizer is lower than 0.1ohm in VW/Bypass mode or lower than 0.05ohm in TC modes, the OLED screen will display “Atomizer Low”.

Atomizer Short-circuit Protection:

When an atomizer short-circuit occurs, the OLED Screen will display “Atomizer Short”.

Temperature Alert:

If the internal temperature of the device is over 70°C(or 158˚F) , the output will shut off automatically and the screen will display “Device too hot”.

Temperature Protection:

In TC modes, if the actual temperature of coil reaches the set temperature, the device shows “Temp Protection”.

Weak Battery Alert:

In TC/VW/Bypass mode, when the device installed with an atomizer is working and the voltage of battery is below 2.9V, the device shows “Weak Battery”. Meanwhile, the output power will be reduced accordingly

We will be happy to hear your thoughts